Product Summary:

The EG4 12000XP Hybrid Inverter is a powerful, high-capacity solution designed for both off-grid and hybrid energy systems. Delivering up to 12,000W split-phase output from battery and supporting up to 24,000W PV input, it provides reliable, efficient power for whole-home backup and energy independence.

 

With dual MPPTs, the 12000XP maximizes solar production while seamlessly managing energy from solar, batteries, and the grid. Built-in breakers, fast UPS transfer (15–30ms), and advanced system controls ensure uninterrupted operation and dependable performance.

 

Designed with a transformer-free architecture, the 12000XP offers improved efficiency, reduced weight, and simplified installation. With smart features like load control, AC coupling, peak shaving, and remote monitoring, it delivers flexible, intelligent energy management for modern residential and commercial systems.

Ships From: Texas, USA
Warranty: 5 Years
Support: Lifetime USA-Based Tech Support

 

Compatibility

Closed-Loop Communication with Batteries (Off-Grid Non-UL 9540 Installs):

  • All BigBattery Batteries
  • All EG4 Batteries

Power Compatibility:

  • Works with 48V battery systems
  • Supports grid-tied, hybrid, and off-grid installations
  • Compatible with solar + generator input setups

Key Features

  • 12,000W Output Power (Battery) – Reliable power for whole-home and commercial applications
  • Up to 24,000W PV Input – High solar capacity with dual MPPT optimization
  • Split-Phase 120/240V Output – Powers both standard and heavy-duty loads
  • Dual MPPT Inputs – Maximizes solar production across multiple arrays
  • UPS Functionality (15–30ms) – Seamless backup power during outages
  • Transformer-Free Design – Lightweight, efficient, and easy to install
  • Built-In Breakers & Safety – Simplifies installation and enhances protection
  • Smart Energy Management – Supports load control, AC coupling, and peak shaving
  • Remote Monitoring & Control – Track system performance and manage settings from anywhere
  • User-Friendly Interface – Simple setup and system configuration
  • Maintenance-Free Operation – No routine servicing required

A high-performance hybrid inverter built for efficiency, flexibility, and reliable energy control – ideal for powering modern homes and businesses.

.

See More On YouTube

 

 

 

 

Inverter Downloads

SKU: INV030
Spec Sheet:DownloadDOWNLOAD
User Manual:DownloadDOWNLOAD
UL1741 Certificate:DownloadDOWNLOAD
WiFi Configuration Guide:DownloadDOWNLOAD
CEC Listing – EG4 12000XP:Go to linkGO TO LINK

Inverter Specifications

Nominal AC Voltage:120/240VAC | 120/208VAC (L1/L2/N required)
Frequency (Grid | Generator):60 Hz (Default) | 50 Hz (Configurable)
Max Continuous AC Current (Grid | Generator):100A @ 240VAC | 62.5A @ 240VAC
Max AC Input Power:24000W
AC Bypass (Grid | Generator):100A | 90A
Recommended Generator Capacity:6000W – 15000W
Output Voltage:120/240VAC | 208VAC
Output Frequency:60 Hz (Default) | 50 Hz (Configurable)
Max Continuous Output Current:50A @ 240VAC | 57.7A @ 208VAC
Nominal Output Power (without PV):12000W @ 240V | 12000W @ 208V
Nominal Output Power (with PV):12000W @ 240V | 12000W @ 208V
Max Continuous Wattage:12000W (L1/L2) | 6000W (L1-N/L2-N)
Surge Capacity:18000W (5 sec) | 15000W (10 sec)
Power Factor:0.99
Total Harmonic Distortion:<3%
Switching Time:<10 ms (Single) | <20 ms (Parallel)
No. of MPPTs (Inputs per MPPT):2 (2)
Max Input Current:35A / 35A
Max Short Circuit Input Current:44A / 44A
DC Input Voltage Range:100 – 480VDC
Min Start Up Voltage:100VDC
MPPT Operating Voltage Range:120 – 385VDC
Nominal MPPT Voltage:320VDC
Max Utilized PV Power:24000W (12000W per MPPT)
Max Recommended PV Input:28000W (14000W per MPPT)
Efficiency:99% (MPPT) | 93.5% (PV to Loads) | 92.8% (PV to Battery) | 92.5% (AC to Battery) | 90.2% (Battery to Loads)
Idle Consumption (Standby Mode):<70W
Nominal Voltage:48VDC
Battery Voltage Range:46.4 – 60VDC
Max Charge / Discharge Current:250A
Max Charge / Discharge Power:12000W
DC Cut-Off Voltage:59VDC
Recommended Battery Capacity per Inverter:>400Ah
Max Parallel Connections:6
Protection Rating:IP20
Communication Interface:RS485 / CANBus / WiFi
Operating Temperature (Full Load):32ºF – 113ºF (0ºC – 45ºC)
Storage Temperature:5ºF – 140ºF (-15ºC – 60ºC)
Altitude:<6,561 ft (2000 m)
Relative Humidity:5 – 95% (Non-Condensing)
Typical Noise Emission:<60 dB
Cooling Method:Fan
Weight:104.7 lbs (47.5 kg)
Depth:5.9 in (150 mm)
Width:20.9 in (530 mm)
Height:34.25 in (870 mm)

Compare Inverter

5-Year EG4 Manufacturer Warranty

.

See More On YouTube

 

 

 

 

Inverter Downloads

SKU: INV030
Spec Sheet:DownloadDOWNLOAD
User Manual:DownloadDOWNLOAD
UL1741 Certificate:DownloadDOWNLOAD
WiFi Configuration Guide:DownloadDOWNLOAD
CEC Listing – EG4 12000XP:Go to linkGO TO LINK

Inverter Specifications

Nominal AC Voltage:120/240VAC | 120/208VAC (L1/L2/N required)
Frequency (Grid | Generator):60 Hz (Default) | 50 Hz (Configurable)
Max Continuous AC Current (Grid | Generator):100A @ 240VAC | 62.5A @ 240VAC
Max AC Input Power:24000W
AC Bypass (Grid | Generator):100A | 90A
Recommended Generator Capacity:6000W – 15000W
Output Voltage:120/240VAC | 208VAC
Output Frequency:60 Hz (Default) | 50 Hz (Configurable)
Max Continuous Output Current:50A @ 240VAC | 57.7A @ 208VAC
Nominal Output Power (without PV):12000W @ 240V | 12000W @ 208V
Nominal Output Power (with PV):12000W @ 240V | 12000W @ 208V
Max Continuous Wattage:12000W (L1/L2) | 6000W (L1-N/L2-N)
Surge Capacity:18000W (5 sec) | 15000W (10 sec)
Power Factor:0.99
Total Harmonic Distortion:<3%
Switching Time:<10 ms (Single) | <20 ms (Parallel)
No. of MPPTs (Inputs per MPPT):2 (2)
Max Input Current:35A / 35A
Max Short Circuit Input Current:44A / 44A
DC Input Voltage Range:100 – 480VDC
Min Start Up Voltage:100VDC
MPPT Operating Voltage Range:120 – 385VDC
Nominal MPPT Voltage:320VDC
Max Utilized PV Power:24000W (12000W per MPPT)
Max Recommended PV Input:28000W (14000W per MPPT)
Efficiency:99% (MPPT) | 93.5% (PV to Loads) | 92.8% (PV to Battery) | 92.5% (AC to Battery) | 90.2% (Battery to Loads)
Idle Consumption (Standby Mode):<70W
Nominal Voltage:48VDC
Battery Voltage Range:46.4 – 60VDC
Max Charge / Discharge Current:250A
Max Charge / Discharge Power:12000W
DC Cut-Off Voltage:59VDC
Recommended Battery Capacity per Inverter:>400Ah
Max Parallel Connections:6
Protection Rating:IP20
Communication Interface:RS485 / CANBus / WiFi
Operating Temperature (Full Load):32ºF – 113ºF (0ºC – 45ºC)
Storage Temperature:5ºF – 140ºF (-15ºC – 60ºC)
Altitude:<6,561 ft (2000 m)
Relative Humidity:5 – 95% (Non-Condensing)
Typical Noise Emission:<60 dB
Cooling Method:Fan
Weight:104.7 lbs (47.5 kg)
Depth:5.9 in (150 mm)
Width:20.9 in (530 mm)
Height:34.25 in (870 mm)

Compare Inverter

5-Year EG4 Manufacturer Warranty

×